The High Frequency armature test rig tests the armature by simulating the yoke with a tunnel and tests characteristic of the armature as its complete assembly.
| No. | Name | Description |
|---|---|---|
The details are subject to change and customizable to orders. |
||
| 1 | Turnnel Voltage DPM |
• Minimum Voltage: 0.01 Volts • Maximum Voltage: 200.00 Volts • Resolution : 0.01 Volts • Accuracy : 0.1 Volts |
| 2 | Rotor(ARMATURE) Current DPM |
• Minimum Current: 00.001 Amps • Maximum Current: 19.999 Amps • Resolution : 0.001 Amps • Accuracy : 0.01 Amps |
| 3 | Stator(TUNNEL) Current DPM |
• Minimum Current: 00.001 Amps • Maximum Current: 19.999 Amps • Resolution : 0.001 Amps • Accuracy : 0.01 Amps |
| 4 | Flash Leakage Current Meter |
• Minimum Current: 00.001 Milli Amps • Maximum Current: 19.999 Milli Amps • Resolution : 0.001 Milli Amps • Accuracy : 0.01 Milli Amps |
| 5 | Mechanical Table size | W900mm X L500mm X H850mm |
| 6 | Electrical Panel Size | 900mm X 1500mm X 300 mm |
| 7 | Total Cycle time | 30 Secs (including unloading) |